Range of product | Harmony Timer Relays |
---|---|
Discrete output type | Relay |
Product or component type | Modular timing relay |
Device short name | RE22 |
Nominal output current | 8 A |
Contacts type and composition | 1 C/O timed contact, cadmium free |
---|---|
Time delay type | Off-delay |
Time delay range | 10...100 s 3...30 s 0.05...1 s 30...300 s 30...300 h 30...300 min 3...30 min 3...30 h 0.3...3 s 1...10 s |
Control type | Rotary knob Diagnostic button Potentiometer external |
[Us] rated supply voltage | 24...240 V AC/DC 50/60 Hz |
Release input voltage | <= 2.4 V |
Voltage range | 0.85...1.1 Us |
Supply frequency | 50...60 Hz +/- 5 % |
Connections - terminals | Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
Housing material | Self-extinguishing |
Repeat accuracy | +/- 0.5 % conforming to IEC 61812-1 |
Temperature drift | +/- 0.05 %/°C |
Voltage drift | +/- 0.2 %/V |
Setting accuracy of time delay | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
Time delay type | Off-delay - C- Off-delay relay w/ control signal Off-delay - Ct- Off-delay relay w/ control signal and pause/summation |
Control signal pulse width | 100 ms with load in parallel 30 ms |
Insulation resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
Recovery time | 120 ms on de-energisation |
Immunity to microbreaks | 10 ms |
Power consumption in VA | 3 VA at 240 V AC |
Power consumption in W | 1.5 W at 240 V DC |
Switching capacity in VA | 2000 VA |
Minimum switching current | 10 mA at 5 V DC |
Maximum switching current | 8 A |
Maximum switching voltage | 250 V AC |
Electrical durability | 100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1 |
Mechanical durability | 10000000 cycles |
Rated impulse withstand voltage | 5 kV for 1.2…50 µs conforming to IEC 60664-1 |
Power on delay | 100 ms |
Creepage distance | 4 kV/3 conforming to IEC 60664-1 |
Overvoltage category | III conforming to IEC 60664-1 |
Safety reliability data | MTTFd = 205.4 years B10d = 190000 |
Mounting position | Any position |
Mounting support | 35 mm DIN rail conforming to IEC 60715 |
Status LED | LED backlight green (steady) for dial pointer indication LED yellow (steady) for output relay energised LED yellow (fast flashing) for timing in progress and output relay de-energised LED yellow (slow flashing) for timing in progress and output relay energised |
Function available | C- Off-delay relay w/ control signal-1 C/O Ct- Off-delay relay w/ control signal and pause/summation-1 C/O |
Width | 22.5 mm |
Net weight | 0.1 kg |
Control type | With test button |
Number of functions | 2 |
Dielectric strength | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1 |
---|---|
Standards | UL 508 IEC 61812-1 |
Directives | 2004/108/EC - electromagnetic compatibility 2006/95/EC - low voltage directive |
Product certifications | UL CE CCC CSA GL RCM EAC |
Ambient air temperature for operation | -20…60 °C |
Ambient air temperature for storage | -40…70 °C |
IP degree of protection | IP40 housing: conforming to IEC 60529 IP50 front face: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529 |
Pollution degree | 3 conforming to IEC 60664-1 |
Vibration resistance | 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 15 gn not operating for 11 ms conforming to IEC 60068-2-27 5 gn in operation for 11 ms conforming to IEC 60068-2-27 |
Relative humidity | 95 % at 25…55 °C |
Electromagnetic compatibility | Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 2.6 cm |
Package 1 Width | 8.2 cm |
Package 1 Length | 9.5 cm |
Package 1 Weight | 99.0 g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 40 |
Package 2 Height | 15.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 4.532 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 640 |
Package 3 Height | 60.0 cm |
Package 3 Width | 80.0 cm |
Package 3 Length | 60.0 cm |
Package 3 Weight | 79.78 kg |